Air bleed output
Control enabled
Enables the motor/valve outputs.
Note: Use caution when enabling this before tuning the PID settings.
Output mode
•PWM - Control of a pneumatic valve that controls a wastegate/dumpvalve.
•Position control - PID control of a motorized valve (E-gate or E-throttle)
Motor PWM frequency
1000-12000Hz. Low frequencies improve motor force and reduce heat dissipation.
Higher frequencies lower audible motor whine.
Recommended: MaxxECU GEN1: 2000Hz, MaxxECU GEN2: 9000Hz
Output test
test mode
Enables a test mode to either send a fixed duty or a fixed target position.
•Test duty - Sets a fixed output duty. Used to test motor direction before enabling PID.
•Test position - Overrides the target page for PID tuning.
test duty / target position
Specifies the fixed duty cycle or target position used when the test is enabled.
PID GAINs
Specifies whether the P, I, and D gains use fixed values or dynamic tables.
•Fixed - Uses fixed P,I and D gain values. Simple setup for stable and predictable conditions.
•PID tables - Instead of fixed values, dynamic tables for P,I and D is available. Allows gain adjustments across load, RPM, or other axes for higher accuracy and adaptability.
P gain
The Proportional gain determines how strongly the controller reacts to the current error between the target and the process value.
A higher P gain increases reaction speed and responsiveness.
Too high can cause overshoot or instability.
Too low makes the system slow or unresponsive.
Use P gain to set how aggressively the controller should correct the error on each cycle.
I gain
The Integral gain controls how the PID controller accumulates and corrects long-term steady-state error over time.
The error is multiplied by I gain and accumulated every cycle. Optional I limiters can constrain the total integral to prevent windup.
A higher I gain improves accuracy but can cause oscillation or slow response if too aggressive.
Resets to zero when controller is disabled.
If error is small but consistent, the I term builds up gradually and increases the duty output to eliminate the offset.
Use I gain to fine-tune how strongly and how quickly long-term errors are corrected.
D gain
The Derivative gain reacts to how quickly the error is changing over time, helping to dampen the system response and reduce overshoot.
The result is subtracted from the output to slow down fast error changes.
The change in error ( delta error) is smoothed using an exponential filter.
Damping effect: reduces overshoot and instability caused by fast-changing signals.
A higher D gain makes the system more resistant to sudden changes but may slow the response too much.
Use D gain to smooth out sharp movements and improve control during fast transitions or ramping.
Recommended PID for the Air Bleed: 10-200 / 10-200 / 50-200
HYsteresis
Hysteresis when the motor changes direction. Used to prevent small steady-state oscillations. 0-3%
I limiter
This parameter controls how the integral (I) term is limited in the PID controller. It determines which strategy is used to prevent integral wind-up.
•default - Applies the same limit to both positive and negative accumulation. Simple and safe for most use cases
•table - Uses a I Limiter Table to scale the limit dynamically. Applies limit symmetrically, allowing both positive and negative integral values. Ideal when dynamic conditions affect how much correction is safe.
FeeD-forward
Feed-forward adds a predefined duty directly to the PID output based on system input, improving response time and reducing reliance on feedback. Useful for overcoming known forces like spring pressure in actuators.
•Disabled - no feed-forward applied.
•Enabled - The result is added before PID terms (P, I, D). Provides an immediate output response even before error builds up. Reduces the work the PID controller must do, especially the integral term. Ideal for predictable systems, e.g., boost control where duty vs. target is known.
end-stop damping
end-stop damping (opening / closing)
Slows down target change close to the end of range to prevent hitting the mechanical limits at high speed.
end-stop current limiting
end-stop current limiter
Limits the current when the actuator is at either end-stop to prevent excessive force and motor overheating in case of position inaccuracies
Mandatory for E-gate control and E-throttle control, where the valve must be fully closed (0% target).
force valve closed
Applies a constant force to close the valve fully when the target position is 0%.
Set a low current at low boost to prevent motor overheating, and a higher current at boost to prevent the valve from leaking.